E0001. General remarks

E0001. General remarks

Design:

  • cast steel according ASTM A-216-WCC or WCB or equal to DIN;
  • stainless steel according ASTM A351-CF8M or CF8C or equal to DIN.

Without special notes the standard will be:

  • non Ex model and suitable for EEx(i) application;
  • sealing minimal IP65 according IEC/EN-60529;
  • transmitters signal output 4 -20mA with HART protocol.

To compare pressure traps form PN into lbs ANSI-B use:

  • PN 10 - 150 lbs;
  • PN 16 - 150 lbs;
  • PN 40 - 300 lbs;
  • PN 100 - 600 lbs.

To compare pipe diameters DIN - ANSI use:

  • DN15 - 0,5'';
  • DN20 - 0,75'';
  • DN25 - 1'';
  • DN40 - 1,5'';
  • DN50 - 2'';
  • DN80 - 3'';
  • DN100 - 4'';
  • DN150 - 6'';
  • DN200 - 8'';
  • DN250 - 10''.

Variation

Quantum discount is possible. Special conditions like material and/or test certification are not included.

Abbreviations Description Remark
SS Stainless steel Quality AISI 304 of 316
DCS Distributed Control System
DN Nominal diameter in mm According DIN 2401 part 1
PN Nominal pressure According DIN 2402
lbs Nominal pressure According ANSI-B 16.5
inch Nominal diameter in mm According ANSI-B 16.5
SCV Short cone venturi
NPT Screw thread according American standard
PTFE Polytetrafluorethylene (Teflon/Fluon)
EEx i Intrinsic safe design According IEC 60079-11
Eex d Explosive safe application, compression resistant According IEC 60079-1
WD Water resistant IP 55 According IEC 60529
PLC Programmable Logic Controller
PVC Poly vinyl chloride
TC Thermo couple
Pt100 Electrical resistant